{"id":298,"date":"2026-09-27T05:30:32","date_gmt":"2026-09-27T05:30:32","guid":{"rendered":"https:\/\/chengguangenergy.com\/"},"modified":"2026-09-27T05:30:32","modified_gmt":"2026-09-27T05:30:32","slug":"solar-storage-battery","status":"publish","type":"post","link":"https:\/\/chengguangenergy.com\/ar\/solar-storage-battery\/","title":{"rendered":"Solar Storage Battery: Solar Batteries for Off-Grid &#038; Backup"},"content":{"rendered":"<p>A <strong>solar storage battery<\/strong> stores photovoltaic energy for use when the sun is not shining. Solar duty is the hardest working cycle in lead-acid service: a daily charge-discharge cycle, often to 50% or deeper, in locations where the ambient temperature may exceed 40 \u00b0C. The battery that survives this is a <strong>deep cycle<\/strong> design \u2014 not a starting battery.<\/p>\n<p>Chengguang supplies solar storage through two channels: its heavy-duty flooded models for cost-driven cyclic duty, and sealed AGM\/GEL batteries manufactured to order for off-grid and backup installations.<\/p>\n<h2>Key Takeaways<\/h2>\n<ul>\n<li><strong>Core rule<\/strong> \u2014 Solar duty = daily deep cycling to 50%+ DoD \u2014 requires deep-cycle, not starting, batteries.<\/li>\n<li><strong>Options<\/strong> \u2014 Flooded (cost-driven), AGM (sealed), GEL (longest cycle life) \u2014 all need the correct charge-controller voltage.<\/li>\n<li><strong>\u062a\u0634\u064a\u0646\u063a\u0648\u0627\u0646\u063a<\/strong> \u2014 145G51\/190H52 suit cyclic duty (80% DoD tested); AGM\/GEL solar banks made to order.<\/li>\n<li><strong>Sizing example<\/strong> \u2014 1,000 Wh\/day \u2192 391 Ah at 50% DoD with 2 autonomy days.<\/li>\n<\/ul>\n<h2>What Solar Duty Demands<\/h2>\n<table>\n<thead>\n<tr>\n<th>Requirement<\/th>\n<th>Why<\/th>\n<th>Battery Attribute<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Deep daily cycling<\/td>\n<td>50\u201380% DoD every night<\/td>\n<td>Thick plates, Pb-Sb or VRLA construction<\/td>\n<\/tr>\n<tr>\n<td>Heat tolerance<\/td>\n<td>Rooftop\/outdoor installs exceed 40 \u00b0C<\/td>\n<td>Low water loss, temperature-rated<\/td>\n<\/tr>\n<tr>\n<td>Long service life<\/td>\n<td>Off-grid systems run 5\u201310+ years<\/td>\n<td>High cycle count at rated DoD<\/td>\n<\/tr>\n<tr>\n<td>Charge-controller compatibility<\/td>\n<td>MPPT\/PWM setpoints vary by chemistry<\/td>\n<td>Correct float\/absorb voltage<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Solar Battery Options<\/h2>\n<table>\n<thead>\n<tr>\n<th>Type<\/th>\n<th>Cycle Life (50% DoD)<\/th>\n<th style=\"text-align: right;\">Maintenance<\/th>\n<th style=\"text-align: right;\">Best For<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Flooded deep cycle<\/td>\n<td>300\u2013500 cycles<\/td>\n<td style=\"text-align: right;\">Watering required<\/td>\n<td style=\"text-align: right;\">Cost-driven off-grid<\/td>\n<\/tr>\n<tr>\n<td>AGM (VRLA)<\/td>\n<td>400\u2013800 cycles<\/td>\n<td style=\"text-align: right;\">None<\/td>\n<td style=\"text-align: right;\">Sealed off-grid, cabin, RV<\/td>\n<\/tr>\n<tr>\n<td>GEL (VRLA)<\/td>\n<td>Highest (best cycle life)<\/td>\n<td style=\"text-align: right;\">None<\/td>\n<td style=\"text-align: right;\">Longest cycle life, float service<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Capacity vs Discharge Rate (Peukert)<\/h2>\n<p>A battery&#8217;s usable Ah shrinks as discharge current rises. A 100 Ah (C20) unit is rated at a 5 A draw over 20 hours; at heavier loads it delivers less:<\/p>\n<table>\n<thead>\n<tr>\n<th>Load (vs C20 rate)<\/th>\n<th style=\"text-align: right;\">Effective Capacity<\/th>\n<th style=\"text-align: right;\">Typical 100 Ah (C20) Bank<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>5 A (C20, 20 h)<\/td>\n<td style=\"text-align: right;\">~100%<\/td>\n<td style=\"text-align: right;\">~100 Ah<\/td>\n<\/tr>\n<tr>\n<td>25 A (C5, 5 h)<\/td>\n<td style=\"text-align: right;\">~80\u201385%<\/td>\n<td style=\"text-align: right;\">~80\u201385 Ah<\/td>\n<\/tr>\n<tr>\n<td>50 A (C2, 2 h)<\/td>\n<td style=\"text-align: right;\">~65\u201375%<\/td>\n<td style=\"text-align: right;\">~65\u201375 Ah<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Size the bank for the highest sustained load, not the daily average. A 1,000 W inverter at 12 V pulls ~83 A (plus inverter losses) \u2014 at that rate a 200 Ah bank delivers closer to 130\u2013150 Ah before voltage sags.<\/p>\n<h2>The Chengguang Solar Range<\/h2>\n<p>Chengguang&#8217;s catalog heavy-duty models are the flooded option for cyclic duty; AGM\/GEL are produced to order for sealed solar installations.<\/p>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th style=\"text-align: right;\">C20 (Ah)<\/th>\n<th>Construction<\/th>\n<th>Solar Suitability<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>95E41<\/td>\n<td style=\"text-align: right;\">100<\/td>\n<td>Flooded SLI<\/td>\n<td>Light backup only<\/td>\n<\/tr>\n<tr>\n<td>105D31<\/td>\n<td style=\"text-align: right;\">90<\/td>\n<td>Flooded SLI<\/td>\n<td>Light backup only<\/td>\n<\/tr>\n<tr>\n<td>145G51 (N150)<\/td>\n<td style=\"text-align: right;\">120\u2013135<\/td>\n<td>Flooded heavy duty, thick Pb-Sb<\/td>\n<td>Cyclic duty (80% DoD tested)<\/td>\n<\/tr>\n<tr>\n<td>190H52 (N200)<\/td>\n<td style=\"text-align: right;\">200<\/td>\n<td>Flooded heavy duty, thick Pb-Sb<\/td>\n<td>Cyclic duty (80% DoD tested)<\/td>\n<\/tr>\n<tr>\n<td>AGM \/ GEL (to order)<\/td>\n<td style=\"text-align: right;\">50\u2013200+<\/td>\n<td>VRLA sealed<\/td>\n<td>Full deep cycle<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Sizing a Solar Battery Bank<\/h2>\n<ol>\n<li><strong>Calculate daily load<\/strong> in watt-hours (Wh) and convert to Ah at system voltage (Wh \u00f7 V = Ah).<\/li>\n<li><strong>Set the DoD budget.<\/strong> Bank Ah required = daily Ah \u00f7 allowable DoD \u00f7 0.85 (round-trip efficiency).<\/li>\n<li><strong>Add autonomy days<\/strong> for cloudy periods: multiply by the number of days the system must run without sun.<\/li>\n<li><strong>Match the charge controller.<\/strong> Set absorb\/float voltages to the battery chemistry \u2014 14.4\u201314.8 V absorb for AGM, lower float for GEL. An incorrect setpoint is the leading cause of early solar battery failure.<\/li>\n<\/ol>\n<p><strong>Example sizing:<\/strong> a 1,000 Wh\/day cabin load at 12 V = 83 Ah\/day. At 50% DoD with 2 autonomy days: 83 \u00f7 0.5 \u00f7 0.85 \u00d7 2 = <strong>391 Ah<\/strong> \u2014 roughly a 2 \u00d7 190H52 (200 Ah each) parallel bank, or a matched AGM\/GEL bank to order.<\/p>\n<h2>Series \/ Parallel Configuration<\/h2>\n<table>\n<thead>\n<tr>\n<th>Configuration<\/th>\n<th>Voltage<\/th>\n<th style=\"text-align: right;\">Capacity<\/th>\n<th>When to Use<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Single battery<\/td>\n<td>12 V<\/td>\n<td style=\"text-align: right;\">as rated<\/td>\n<td>Small systems (&lt;100 Ah)<\/td>\n<\/tr>\n<tr>\n<td>2 \u00d7 in <strong>parallel<\/strong><\/td>\n<td>12 V<\/td>\n<td style=\"text-align: right;\">doubled<\/td>\n<td>12 V systems needing more Ah<\/td>\n<\/tr>\n<tr>\n<td>2 \u00d7 in <strong>series<\/strong><\/td>\n<td>24 V<\/td>\n<td style=\"text-align: right;\">same as one<\/td>\n<td>24 V inverters \u2014 halves current and cable loss<\/td>\n<\/tr>\n<tr>\n<td>4 \u00d7 (2S2P)<\/td>\n<td>24 V<\/td>\n<td style=\"text-align: right;\">doubled<\/td>\n<td>Larger 24 V banks<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>All batteries in a string must be the same model, age, and capacity. Mismatched strings develop unequal state-of-charge \u2014 one battery overcharges and gasses while another starves and sulfates.<\/p>\n<h2>Buying Considerations<\/h2>\n<ol>\n<li><strong>Deep cycle, not starting.<\/strong> A starting battery in a solar array will fail in months.<\/li>\n<li><strong>Series\/parallel strings<\/strong> must use identical batteries of the same age and capacity.<\/li>\n<li><strong>Temperature derating.<\/strong> At 40 \u00b0C, derate service life and check the battery&#8217;s temperature rating before specifying.<\/li>\n<li><strong>Sealed for inaccessible installs.<\/strong> If the bank is in a sealed box or indoors, AGM\/GEL avoids hydrogen venting and watering.<\/li>\n<\/ol>\n<h2>Charge Controller Matching<\/h2>\n<p>The charge controller \u2014 MPPT or PWM \u2014 is what keeps a solar battery alive. The single most common cause of early solar-battery death is an absorb\/float voltage set for the wrong chemistry:<\/p>\n<table>\n<thead>\n<tr>\n<th>Chemistry<\/th>\n<th>Absorb Voltage<\/th>\n<th>Float Voltage<\/th>\n<th>\u0645\u0644\u0627\u062d\u0638\u0627\u062a<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Flooded deep cycle<\/td>\n<td>14.4\u201314.8 V<\/td>\n<td>13.2\u201313.8 V<\/td>\n<td>Periodic equalization; water check<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0627\u062c\u062a\u0645\u0627\u0639 \u0627\u0644\u0633\u0646\u0648\u064a \u0627\u0644\u0639\u0627\u0645<\/td>\n<td>14.4\u201314.8 V<\/td>\n<td>13.2\u201313.6 V<\/td>\n<td>Never equalize aggressively<\/td>\n<\/tr>\n<tr>\n<td>GEL<\/td>\n<td>14.1\u201314.4 V<\/td>\n<td>13.2\u201313.5 V<\/td>\n<td>Lower absorb \u2014 GEL is overcharge-sensitive<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Set the controller to the <strong>battery&#8217;s<\/strong> chemistry, not the panel&#8217;s output. MPPT controllers extract more energy in partial light; PWM is cheaper and adequate for small systems \u2014 but both must have the correct voltage setpoints.<\/p>\n<h2>Temperature Derating<\/h2>\n<p>Lead-acid chemistry is temperature-sensitive, and solar banks often live in hot, exposed locations:<\/p>\n<ul>\n<li><strong>Above 25 \u00b0C<\/strong>, capacity rises slightly but <strong>service life falls<\/strong> \u2014 every 8\u201310 \u00b0C roughly halves VRLA design life.<\/li>\n<li><strong>At 40 \u00b0C ambient<\/strong>, derate expected service life and verify the battery&#8217;s temperature rating before specifying.<\/li>\n<li><strong>Below 0 \u00b0C<\/strong>, available capacity drops sharply, and a discharged flooded bank can freeze.<\/li>\n<\/ul>\n<p>A temperature-compensated charge controller (with a battery temp sensor) automatically adjusts voltage setpoints and is worth the small premium for any permanently installed off-grid bank.<\/p>\n<h3>Temperature Compensation Coefficients<\/h3>\n<p>Charge voltage must be lowered as temperature rises. The standard correction is approximately <strong>\u22123 mV\/\u00b0C per cell<\/strong> for flooded and <strong>\u22124 mV\/\u00b0C per cell<\/strong> for AGM\/GEL, referenced to 25 \u00b0C (2.40 V\/cell absorb):<\/p>\n<table>\n<thead>\n<tr>\n<th>Bank Temperature<\/th>\n<th style=\"text-align: right;\">Flooded Absorb (12 V)<\/th>\n<th style=\"text-align: right;\">AGM\/GEL Absorb (12 V)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>25 \u00b0C<\/td>\n<td style=\"text-align: right;\">14.40 V<\/td>\n<td style=\"text-align: right;\">14.40 V<\/td>\n<\/tr>\n<tr>\n<td>35 \u00b0C<\/td>\n<td style=\"text-align: right;\">14.22 V<\/td>\n<td style=\"text-align: right;\">14.16 V<\/td>\n<\/tr>\n<tr>\n<td>45 \u00b0C<\/td>\n<td style=\"text-align: right;\">14.04 V<\/td>\n<td style=\"text-align: right;\">13.92 V<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>A fixed 14.40 V absorb on a 45 \u00b0C bank overcharges it by ~0.36 V \u2014 enough to gas a GEL bank dry within months. A temperature sensor (or a manual seasonal adjustment) is the fix.<\/p>\n<h2>Autonomy Days &amp; DoD Budget<\/h2>\n<p>Two variables dominate solar-bank sizing \u2014 and they trade off against each other:<\/p>\n<table>\n<thead>\n<tr>\n<th>Variable<\/th>\n<th>Effect on Bank Size<\/th>\n<th>Effect on Battery Life<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Deeper DoD budget (80% vs 50%)<\/td>\n<td>Smaller\/cheaper bank<\/td>\n<td>Shorter life (~1.5\u00d7 shorter)<\/td>\n<\/tr>\n<tr>\n<td>More autonomy days<\/td>\n<td>Larger bank<\/td>\n<td>Longer life (shallower average DoD)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>A 50% DoD budget with 2\u20133 autonomy days is the standard off-grid starting point; it roughly doubles cycle life versus an 80% budget while still covering cloudy stretches. For a 1,000 Wh\/day cabin: 83 Ah\/day \u00f7 0.5 \u00f7 0.85 = 196 Ah \u00d7 2 days = <strong>391 Ah<\/strong>.<\/p>\n<h2>Panel-to-Battery Balance (Worked Example)<\/h2>\n<p>A battery is only as healthy as the charge it receives. For the 1,000 Wh\/day cabin above, the array must replace roughly 1,000 \u00f7 0.8 \u2248 1,250 Wh\/day once controller, wiring, and round-trip losses are counted. At 4.5 peak-sun hours that is 1,250 \u00f7 4.5 \u2248 <strong>280 W<\/strong> of panel; add a 20% margin for cloud and panel aging \u2192 a ~330 W array. An undersized array or controller leaves the bank chronically undercharged \u2014 the single most common cause of early sulfation and capacity loss off-grid.<\/p>\n<h2>Depth of Discharge vs Cycle Life<\/h2>\n<p>The deeper the daily discharge, the fewer cycles a lead-acid bank delivers \u2014 this trade-off drives solar sizing:<\/p>\n<table>\n<thead>\n<tr>\n<th>Daily DoD<\/th>\n<th style=\"text-align: right;\">Approx. Cycle Life (Flooded)<\/th>\n<th style=\"text-align: right;\">Approx. Cycle Life (AGM\/GEL)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>30%<\/td>\n<td style=\"text-align: right;\">~800\u20131,200<\/td>\n<td style=\"text-align: right;\">~1,200\u20131,800<\/td>\n<\/tr>\n<tr>\n<td>50%<\/td>\n<td style=\"text-align: right;\">~300\u2013500<\/td>\n<td style=\"text-align: right;\">~400\u2013800<\/td>\n<\/tr>\n<tr>\n<td>80%<\/td>\n<td style=\"text-align: right;\">~150\u2013250<\/td>\n<td style=\"text-align: right;\">~250\u2013400<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Halving the DoD budget (80% \u2192 50%) roughly doubles cycle life \u2014 which is why the 50%-DoD starting point is standard off-grid practice, and why an undersized bank costs more in the long run than a larger one.<\/p>\n<h2>Placement, Venting &amp; Safety<\/h2>\n<ul>\n<li><strong>Vent flooded banks<\/strong> \u2014 off-gassing hydrogen must vent to open air, never into a sealed room.<\/li>\n<li><strong>Sealed (AGM\/GEL) for enclosed installs<\/strong> \u2014 no watering, minimal gassing, safe in cabins and RVs.<\/li>\n<li><strong>Temperature<\/strong> \u2014 keep the bank out of direct sun; heat is the fastest way to shorten lead-acid life.<\/li>\n<li><strong>Fusing<\/strong> \u2014 every string needs over-current protection sized to the cable, not the load.<\/li>\n<\/ul>\n<h2>Off-Grid vs Backup (Hybrid) Solar<\/h2>\n<p>Two solar use cases put different demands on the battery:<\/p>\n<table>\n<thead>\n<tr>\n<th>Use Case<\/th>\n<th>Daily Cycling<\/th>\n<th>Battery Priority<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Off-grid (no grid)<\/td>\n<td>Deep daily cycle, 50% DoD<\/td>\n<td>Cycle life, DoD tolerance<\/td>\n<\/tr>\n<tr>\n<td>Backup \/ hybrid (grid-tied)<\/td>\n<td>Float most of the time, cycles on outage<\/td>\n<td>Float life, low self-discharge<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>An off-grid bank needs deep-cycle construction and a DoD budget; a backup bank spends most of its life at float and only cycles during outages, so VRLA (AGM\/GEL) float life matters more than cycle count. Sizing is the same formula either way \u2014 the difference is which battery attribute you optimize.<\/p>\n<h2>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h2>\n<p><strong>How many batteries do I need for off-grid solar?<\/strong> Size by daily load: required Ah = daily Ah \u00f7 allowable DoD \u00f7 0.85, then multiply by autonomy days for cloudy periods.<\/p>\n<p><strong>Flooded or AGM for solar?<\/strong> Flooded for cost-driven, accessible installs; AGM\/GEL for sealed or inaccessible banks. Both require a charge controller set to the correct chemistry voltage.<\/p>\n<p><strong>How long does a solar battery last?<\/strong> 5\u201310+ years for a properly sized and maintained deep-cycle bank; an undersized bank cycled past 80% DoD fails much sooner.<\/p>\n<p><strong>Do I need a special charge controller?<\/strong> Any controller works if its absorb\/float voltages match the battery chemistry \u2014 but a temperature-compensated MPPT controller is worth the premium for permanent off-grid installs.<\/p>\n<p><strong>Can I mix old and new batteries in a bank?<\/strong> No \u2014 all batteries in a string must be the same model, age, and capacity, or the bank develops unequal state-of-charge and fails early.<\/p>\n<h2>Related Articles<\/h2>\n<ul>\n<li><a href=\"\/ar\/deep-cycle-battery\/\">Deep Cycle Battery Guide<\/a><\/li>\n<li><a href=\"\/ar\/ups-battery\/\">UPS Battery Guide<\/a><\/li>\n<li><a href=\"\/ar\/agm-battery\/\">AGM Battery Guide<\/a><\/li>\n<li><a href=\"\/ar\/jis-190h52\/\">190H52 Battery<\/a><\/li>\n<li><a href=\"\/ar\/jis-145g51\/\">145G51 Battery<\/a><\/li>\n<li><a href=\"https:\/\/technical.chengguangenergy.com\/battery-testing\/c20-capacity\/\" rel=\"nofollow\">C20 Capacity \u2014 Complete Guide<\/a><\/li>\n<li><a href=\"https:\/\/technical.chengguangenergy.com\/battery-technology\/vrla\/\" rel=\"nofollow\">VRLA Battery Technology Reference<\/a><\/li>\n<li><a href=\"https:\/\/chengguangenergy.com\/ar\/contact\/\">Request Solar OEM Quote<\/a><\/li>\n<\/ul>\n<h2>Sources &amp; Verification<\/h2>\n<p>Specifications on this page are sourced from Chengguang Power Tech factory technical documentation and tested to JIS D 5301, DIN EN 50342-1, SAE J537, and IEC 60095-1. Contact Chengguang for the exact data sheet. Every batch ships with a Certificate of Analysis (CoA).<\/p>\n<p><em>Author: Chengguang Engineering Team \u00b7 Reviewed: IATF 16949 Quality Department \u00b7 Last updated: 2026-08-19<\/em><\/p>","protected":false},"excerpt":{"rendered":"<p>Solar storage battery guide \u2014 deep cycle vs starting for solar, flooded\/AGM\/GEL options, sizing a solar bank (worked example), and charge-controller matching.<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":"","_llm_markdown_disabled":false},"categories":[125],"tags":[],"class_list":["post-298","post","type-post","status-publish","format-standard","hentry","category-battery-technology"],"_links":{"self":[{"href":"https:\/\/chengguangenergy.com\/ar\/wp-json\/wp\/v2\/posts\/298","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chengguangenergy.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/chengguangenergy.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/chengguangenergy.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chengguangenergy.com\/ar\/wp-json\/wp\/v2\/comments?post=298"}],"version-history":[{"count":1,"href":"https:\/\/chengguangenergy.com\/ar\/wp-json\/wp\/v2\/posts\/298\/revisions"}],"predecessor-version":[{"id":801,"href":"https:\/\/chengguangenergy.com\/ar\/wp-json\/wp\/v2\/posts\/298\/revisions\/801"}],"wp:attachment":[{"href":"https:\/\/chengguangenergy.com\/ar\/wp-json\/wp\/v2\/media?parent=298"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/chengguangenergy.com\/ar\/wp-json\/wp\/v2\/categories?post=298"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/chengguangenergy.com\/ar\/wp-json\/wp\/v2\/tags?post=298"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}