title: "57117 (DIN70) Battery for UPS / Backup Power: Application Guide"
id: "323"
type: "post"
slug: "din-57117-ups"
published_at: "2026-11-16T05:30:32+00:00"
modified_at: "2026-11-16T05:30:32+00:00"
url: "https://chengguangenergy.com/ru/din-57117-ups/"
markdown_url: "https://chengguangenergy.com/ru/din-57117-ups.md"
excerpt: "57117 (DIN70) 70 Ah DIN battery for ups / backup power — 600 A (EN) (ref.) CCA, 273 × 174 × 175 mm (ref.) case, B13 (bottom rail) mounting."
taxonomy_category:
  - "Battery Technology"
---

> Part of the **[UPS / Backup Power](/ru/ups-battery/)** guide.

The 57117 (DIN70) is a 70 Ah DIN battery in a 273 × 174 × 175 mm (ref.) case — standby duty wants low self-discharge, reliable float life, and enough capacity for the outage window.

## Key Takeaways

- **Spec** — 70 Ah C20, 600 A (EN) (ref.) CCA, 273 × 174 × 175 mm (ref.), B13 (bottom rail) hold-down, DIN post.
- **Application** — ups / backup power.
- **Fit** — standby duty wants low self-discharge, reliable float life, and enough capacity for the outage window.
- **Usable capacity** — ~35 Ah at 50% DoD for deep-cycling duty.

## DIN70 Specifications

| Parameter | Specification |
| --- | --- |
| Model | 57117 |
| Also Known As | DIN70 |
| Стандартный | DIN |
| Capacity (C20) | 70 Ah |
| CCA Rating | 600 A (EN) (ref.) |
| Dimensions (L×W×H) | 273 × 174 × 175 mm (ref.) |
| Terminal Type | DIN post |
| Hold-Down | B13 (bottom rail) |

## UPS / Backup Power Requirements → DIN70 Match

| Requirement | DIN70 | Verdict |
| --- | --- | --- |
| Standby capacity (C20) | 70 Ah | ✓ |
| Float / standby service | Sealed maintenance-free (Ca-Ca) | ✓ |
| Self-discharge | Low (sealed Ca-Ca alloy) | ✓ |
| Voltage | 12 V | ✓ |

## Cross-Standard Equivalent

| Стандартный | Equivalent | Confidence | Note |
| --- | --- | --- | --- |
| BCI | Group 48 (H6) | Medium | Same footprint — verify terminals |

> Cross-standard matches are dimensional approximations. Always verify tray length, terminal type, and hold-down before substituting.

## Fitment Considerations

- UPS service is float — the battery sits fully charged most of its life, so low self-discharge and sealed design win.
- Size for the outage window: a 70 Ah battery backs a small load for hours, a server room for minutes.
- **Temperature** — keep the battery at 20–25 °C; every 8 °C above roughly halves float life.

## What Buyers Should Ask

Before ordering the 57117 Battery — DIN70 for UPS backup, confirm these points with the supplier:

- **CCA standard** — 600 A (EN); verify the test method (EN vs SAE) printed on the label matches your region’s convention.
- **Capacity** — 70 Ah; enough reserve for the UPS backup accessory load.
- **Case fit** — 273 × 174 × 175 mm (industry ref.); measure the tray and confirm the B13 (bottom rail) hold-down.
- **Terminals** — Standard DIN post; check polarity and post type against the harness.
- **Data sheet** — request the production Certificate of Analysis (CoA) for exact batch values.

## Frequently Asked Questions

**How long will it back up a load?** Runtime = usable Ah ÷ load. For UPS float service, the 70 Ah rating defines the outage window at 50% DoD.

**How often to replace a UPS battery?** 3–5 years in float service; replace when runtime falls below the required outage window.

**What shortens a UPS battery’s life?** Heat, deep discharge, and infrequent replacement. Keep it cool and replace on schedule.

## Related Articles

- [56638 (DIN66) for UPS / Backup Power](/ru/din-56638-ups/)
- [57219 (DIN72) for UPS / Backup Power](/ru/din-57219-ups/)
- [57117 Battery — Full Specs](/ru/din-57117/)
- [UPS / Backup Power Guide](/ru/ups-battery/)
- [Request OEM Quote](https://chengguangenergy.com/ru/contact/)

## Sources & Verification

Specifications sourced from Chengguang Power Tech factory technical documentation and tested to DIN EN 50342-1, SAE J537, and IEC 60095-1. Figures marked “(ref.)” are third-party manufacturer catalog reference values — always confirm against the production data sheet. Every batch ships with a Certificate of Analysis (CoA).

*Author: Chengguang Engineering Team · Reviewed: IATF 16949 Quality Department · Last updated: 2026-08-26*

## Похожие записи

- 56638 (DIN66) 66 Ah DIN battery for marine — 540 A (SAE) CCA, 278 × 175 × 175–190 mm case, B13 (bottom rail) mounting.
- Automotive battery OEM & private label manufacturing in China — IATF 16949 factory, 7-step OEM process, 6 customization services, 40,000/day capacity since…
- [https://chengguangenergy.com/ru/cca-vs-ah-cold-cranking-amps-battery-capacity-explained/](https://chengguangenergy.com/ru/cca-vs-ah-cold-cranking-amps-battery-capacity-explained/) CCA vs Ah: Cold Cranking Amps vs Amp-Hours Explained for Battery Buyers Direct answer: Cold Cranking Amps (CCA) measures how much current a battery can deliver for a short, high-power burst to start an engine in cold weather. Amp-hours (Ah) measures how much energy the battery stores and how long it can deliver power over…
- 56638 (DIN66) 66 Ah DIN battery for commercial vehicles — 540 A (SAE) CCA, 278 × 175 × 175–190 mm case, B13 (bottom rail) mounting.
- Why Battery Type Selection Matters for Importers When sourcing automotive batteries for your market, choosing the wrong type can cost you in warranty claims, customer satisfaction, and brand reputation. This article breaks down the four battery types available from OEM manufacturers, their ideal applications, and how to determine which types belong in your product lineup….
- JIS battery standard guide — how to read a JIS model number, B00 vs B13 mounting, the 7-model Chengguang JIS range, and JIS vs SAE CCA.

### Добавить комментарий [Отменить ответ](/ru/din-57117-ups/#respond)