57117 (DIN70) Battery for UPS / Backup Power: Application Guide
Part of the UPS / Backup Power guide.
The 57117 (DIN70) is a 70 Ah DIN battery in a 273 × 174 × 175 mm (ref.) case — standby duty wants low self-discharge, reliable float life, and enough capacity for the outage window.
Key Takeaways
- Spec — 70 Ah C20, 600 A (EN) (ref.) CCA, 273 × 174 × 175 mm (ref.), B13 (bottom rail) hold-down, DIN post.
- Application — ups / backup power.
- Fit — standby duty wants low self-discharge, reliable float life, and enough capacity for the outage window.
- Usable capacity — ~35 Ah at 50% DoD for deep-cycling duty.
DIN70 Specifications
| المعلمة | المواصفات |
|---|---|
| Model | 57117 |
| Also Known As | DIN70 |
| قياسي | DIN |
| السعة (C20) | 70 Ah |
| تصنيف CCA | 600 A (EN) (ref.) |
| الأبعاد (الطول × العرض × الارتفاع) | 273 × 174 × 175 mm (ref.) |
| نوع المحطة | DIN post |
| Hold-Down | B13 (bottom rail) |
UPS / Backup Power Requirements → DIN70 Match
| Requirement | DIN70 | Verdict |
|---|---|---|
| Standby capacity (C20) | 70 Ah | ✓ |
| Float / standby service | Sealed maintenance-free (Ca-Ca) | ✓ |
| Self-discharge | Low (sealed Ca-Ca alloy) | ✓ |
| Voltage | 12 V | ✓ |
Cross-Standard Equivalent
| قياسي | Equivalent | Confidence | Note |
|---|---|---|---|
| BCI | Group 48 (H6) | Medium | Same footprint — verify terminals |
Cross-standard matches are dimensional approximations. Always verify tray length, terminal type, and hold-down before substituting.
Fitment Considerations
- UPS service is float — the battery sits fully charged most of its life, so low self-discharge and sealed design win.
- Size for the outage window: a 70 Ah battery backs a small load for hours, a server room for minutes.
- Temperature — keep the battery at 20–25 °C; every 8 °C above roughly halves float life.
What Buyers Should Ask
Before ordering the 57117 Battery — DIN70 for UPS backup, confirm these points with the supplier:
- CCA standard — 600 A (EN); verify the test method (EN vs SAE) printed on the label matches your region’s convention.
- Capacity — 70 Ah; enough reserve for the UPS backup accessory load.
- Case fit — 273 × 174 × 175 mm (industry ref.); measure the tray and confirm the B13 (bottom rail) hold-down.
- Terminals — Standard DIN post; check polarity and post type against the harness.
- Data sheet — request the production Certificate of Analysis (CoA) for exact batch values.
الأسئلة الشائعة
How long will it back up a load? Runtime = usable Ah ÷ load. For UPS float service, the 70 Ah rating defines the outage window at 50% DoD.
How often to replace a UPS battery? 3–5 years in float service; replace when runtime falls below the required outage window.
What shortens a UPS battery’s life? Heat, deep discharge, and infrequent replacement. Keep it cool and replace on schedule.
Related Articles
- 56638 (DIN66) for UPS / Backup Power
- 57219 (DIN72) for UPS / Backup Power
- 57117 Battery — Full Specs
- UPS / Backup Power Guide
- Request OEM Quote
Sources & Verification
Specifications sourced from Chengguang Power Tech factory technical documentation and tested to DIN EN 50342-1, SAE J537, and IEC 60095-1. Figures marked “(ref.)” are third-party manufacturer catalog reference values — always confirm against the production data sheet. Every batch ships with a Certificate of Analysis (CoA).