190H52 Battery (N200): Heavy-Duty Truck & Equipment Battery Specs

Part of the JIS Battery Standard guide.

The 190H52 (N200) is the largest, most powerful battery in the Chengguang range — 200 Ah and 1,100 CCA for heavy-duty trucks, large buses, earthmoving equipment, and stationary engines. Extra-thick plates (3.5–4.0 mm) and massive lead content (45–55 kg) provide starting power for the largest diesel engines.

Key Takeaways

  • Specs — The largest Chengguang battery: 200 Ah, 1,100 CCA, 521 × 278 mm, 45–55 kg.
  • Fitment — Heavy trucks (>8 L diesel), large buses, mining/earthmoving equipment, stationary generators.
  • Handling — Requires two-person handling or a lift; 24 V = two units in series.
  • Build — Pb-Sb grids 3.5–4.0 mm, ribbed high-impact PP case, through-wall intercell welds, 500–800 units/day.

Quick Reference

ParameterSpecification
Model190H52
Also Known AsN200
StandardJIS
Battery TypeHeavy Duty
Nominal Voltage12 V
Capacity (C20)200 Ah
CCA Rating1,100 A (SAE)
Dimensions (L×W×H)521 × 278 × 220–270 mm
Terminal TypeT1 large post
PolarityLeft (−), Right (+) — JIS type [0]
Hold-DownB00 (top frame)
Approximate Weight45–55 kg
Chengguang SKUCG-JIS-190H52

Specification ranges: values are typical production ranges. Exact CCA and Ah vary by batch — request the technical data sheet for your order.

Case & Terminal Identification

The largest JIS case: 521 × 278 mm with T1 large-post terminals. The label reads 190H52 or N200. Weight (45–55 kg) is unmistakable — over 3× a standard car battery — requiring two-person handling or a mechanical lift.

IdentifierValueCheck
Case length521 mmLargest JIS case (H-series)
Case width278 mmWidest heavy-duty case
TerminalT1 large postLarge-diameter post
Weight45–55 kgRequires lift/two-person handling

Vehicle Applications

Heavy-duty trucks (>8 L diesel), large buses and coaches, earthmoving equipment, stationary diesel generators, and mining equipment — the most demanding starting applications.

CategoryCompatible Equipment
Heavy trucksTractor units, dump trucks, concrete mixers
BusesCity buses, intercity coaches
ConstructionLarge excavators, dozers, graders, mining trucks
StationaryLarge diesel generators (prime/standby)
MarineLarge commercial vessel starting

Fitment is a market-based guide — verify tray dimensions, terminal position, and hold-down before ordering. For 24 V systems, run two 190H52 batteries in series.

Regional Markets

RegionDemandSegment
GlobalCommercial aftermarketMining, construction, fleet operators

Manufacturing & Grid Alloy

The 190H52 runs on Chengguang’s heavy-duty line in Jinzhou, Hebei, China:

  • Grid alloy — lead-antimony (Pb-Sb) extra-thick grids (3.5–4.0 mm).
  • Deep-sump design — large electrolyte reservoir for extended service intervals.
  • Case — ribbed high-impact polypropylene for mining/construction duty.
  • Welds — heavy-duty COS and through-the-wall intercell welds for 1,100 A current handling.
  • Throughput — 500–800 units/day.

Testing & Quality Control

TestStandardPass CriteriaCoverage
CCA Cold CrankingSAE J537 at −18 °C>1,100 A100%
Open Circuit Voltage—>12.60 V after formation100%
High-Rate Discharge30-second testVoltage stability100%
Visual Inspection—Case, terminals, label, polarity100%
C20 CapacityIEC 60095-1≥95% of rated 200 AhBatch
Reserve CapacitySAE J537300–400 min typicalBatch
Severe VibrationSAE J5375g RMS, 8 hoursBatch
Thermal Cycling−40 °C to +70 °CNo leakage, CCA retentionBatch
Deep-Cycle Endurance—80% DoDBatch

Charging & Service Life

  • Charge voltage — flooded Pb-Sb absorption 14.4–15.0 V; equalize periodically if specific-gravity spread exceeds 0.030.
  • Service life — 2–4 years in commercial service; the thick plates tolerate the deep cycling and vibration that kill SLI batteries.

Sizing Check — Worked Example

A heavy tractor unit (24 V, >8 L diesel) and overnight reserve:

  1. 24 V series. Two 190H52 units in series give 24 V at 200 Ah and 1,100 CCA — the standard heavy-truck configuration. Use identical age/spec batteries and replace both together.
  2. Reserve capacity. At 300–400 min RC (25 A to 10.5 V), a 190H52 supports a 25 A overnight load for 5–6.7 hours — the reason heavy trucks specify the 190H52 over the 145G51 for long unattended stands.

Cross-Reference

ModelStandardRelationship
N200JISAlias — same case

N200 is the regional designation for the 190H52.

Cross-Standard Equivalents

StandardModelConfidenceNote
—No published BCI/DIN equivalent—JIS-specific case

No published BCI or DIN equivalent exists for this JIS-specific case. Contact Chengguang for OEM cross-referencing support.

OEM & Private Label Availability

The 190H52 is available for OEM manufacturing under your brand from Chengguang Power Tech:

  • Custom label, case color, terminal type, and retail packaging
  • Full batch traceability — raw material lot to shipping container
  • 100% pre-shipment CCA and capacity testing with CoA
  • DG-compliant export packaging (UN 2794 / Class 8)
  • Technical data sheet, MSDS, and Certificate of Analysis per shipment

Request OEM Quote · View OEM Process

Frequently Asked Questions

What engines need a 190H52? Heavy trucks (>8 L diesel), large buses, mining/earthmoving equipment, and large stationary generators.

190H52 vs 145G51? The 190H52 is larger (521 vs 508 mm) with 200 Ah / 1,100 CCA versus 120–135 Ah / 800–900 CCA. 190H52 for heavy trucks/equipment; 145G51 for medium trucks/buses.

How heavy is it? 45–55 kg — use two-person handling or a mechanical lift.

For 24 V systems? Two 190H52 units in series — the standard heavy-truck and equipment 24 V configuration. Replace both together.

Handling and safety? Always wear PPE; use terminal covers during transport; secure with the B00 frame clamp.

Related Models

Author & Factory Credentials

Authored by the Chengguang Engineering Team — application and process engineers at Chengguang Power Tech, an automotive battery manufacturer in Jinzhou, Hebei, China. Content is reviewed by the IATF 16949 Quality Department against production data and third-party test reports before publication.

Factory certifications: IATF 16949 (automotive quality) · ISO 9001 (quality management) · ISO 45001 (occupational safety) · CE marking (EU compliance).

Full test reports and the Certificate of Analysis (CoA) are published on the Battery Database and ship with every order.

Sources & Verification

Specifications on this page are sourced from Chengguang Power Tech factory technical documentation and tested to JIS D 5301, DIN EN 50342-1, SAE J537, and IEC 60095-1. Contact Chengguang for the exact data sheet. Every batch ships with a Certificate of Analysis (CoA).

Author: Chengguang Engineering Team · Reviewed: IATF 16949 Quality Department · Last updated: 2026-08-19

Similar Posts